HeatReclaim Ventilator — VAM series. Model Names. VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Nameor trademark Daikin Europe N.V. Product descrip-tion Model identifier VAM150FCVE VAM250FCVE Specific energy consumption (SEC) Cold climate kWh/ (m².a) Heat reclaim ventilation • VAM-FC9 5 Dimensional drawings 5 - 1 Dimensional Drawings. 560 718 25.4 9.5 12.2 VAM-FC9 4D099260 10 6 hRV- hEAT REcLAIM VENTILATION hrv helps to create a high quality indoor environment the Daikin HRv (Heat Reclaim ventilation) unit recovers heat energy lost through ventilation and maintains a comfortable and clean indoor environment without changes in room temperature. this also reduces the load on the air conditioning system and saves energy. TheDaikin HR V (Heat Reclaim V entilation) r ecovers heat ener gy lost thr ough ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also reduces the load on the air conditioning system and conserves energy. In addition, the HRV interlocks with Daikin's VRV andtraining on VRV or VRF equipment, do not attempt to install, commission or service any Daikin VRV product with this handbook. Instead, the Field Service Technician needs to complete training offered by Daikin AC (Americas), Inc. ("Daikin AC") before attempting any installation, commissioning or service of the VRV product. DAIKIN'Fresh' Air Solusi ventilasi kami yang inovatif dapat mengeluarkan udara yang tercemar di dalam ruangan dan memasukan udara dari luar melalui filter, sehingga Anda dapat menikmati udara segar di dalam ruangan. Ventilation Menyaring PM2.5 dan hemat energi saat melakukan ventilasi. *Dengan Unit Filtrasi PM2.5. Dapat dipasang ulang. HeatReclaim Ventilation The Daikin heat recovery ventilation system modulates the temperature and humidity of incoming fresh air to match indoor conditions. A balance is thus achieved between indoor and outdoor ambients, enabling the cooling or heating load placed on the air conditioning system to be reduced significantly. ofthe Heat Reclaim Ventilator. 6.Message The following messages are displayed. "This function not available." 'LVSOD\HG IRU D IHZ VHFRQGV ZKHQ DQ operation button is pressed and the indoor unit does not have the corresponding function. ,I D QXPEHU RI LQGRRU XQLWV DUH LQ RSHUDWLRQ WKH PHVVDJH ZLOO DSSHDU RQO\ LI QRQH RI WKH fYWMG2M. Product categoryVRV Air Conditioner›Heat Reclaim VentilationModel HRV VAM250GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVESpecificationMODELVAM250GJVEVAM500GJVEVAM650GJVEVAM800GJVEVAM1000GJVEVAM1500GJVEVAM2000GJVEPower Supply1-phase, 220-240 V/ 220 V, 50 HzTemp. ExchangeEf ciency50/60 HzUltra-High%75/7574/7475/7572/7278/7872/7277/77High75/7574/7475/7572/7278/7872/7277/77Low79/7980/ ciency50/60 HzFor HeatingUltra-High%71/7267/ CoolingUltra-High%63/6355/5561/6161/6164/6461/6162/62High63/6355/5561/6161/6164/6461/6162/62Low66/6659/ HzHeatExchangeModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Bypass ModeUltra-HighW137/141248/270342/398599/680635/7601,145/1,3001,289/1,542High120/125225/217300/332517/597567/648991/1,1441,151/1,315Low60/59128/136196/207435/483476/512835/927966/1,039Sound Level 50/60 HzHeat ExchangeModeUltra-HighdBA27-29/ ModeUltra-HighdBA steel plateInsulation MaterialSelf-extinguishable polyurethane foamDimensions HXWXDmm278X810X551306X879X800338X973X832387X1,111X832387X1,111X1,214785X1,619X832785X1,619X1,214Machine Weighkg2432455567129157Heat Exchange SystemAir to air cross ow total heat Sensible heat+latent heat exchangeHeat Exchange Element MaterialSpecially processed non-ammable paperAir FilterMultidirectional brous eecesFanTypeSirocco fanAir ow Rate50/60 HzUltra-Highm3/h250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000High250/250500/500650/650800/8001,000/1,0001,500/1,5002,000/2,000Low155/155320/295500/470700/670860/8401,320/1,2601,720/1,580External Static Pressure50/60 HzUltra-HighPa70/96105/15085/125133/170168/192112/150116/ Duct Diametermmø150ø 200ø 250ø 350Unit ambient condition-15°C–50°CDB, 80%RH or lessAS A PART OF CONTINOUS DEVELOPMENT AND UPGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE/SPECIFICATION MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE. Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. VAM-HVE VAM-HVE Heat Reclaim Ventilator Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP* of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. *Max ESP varies from 130 Pa to 235 Pa depending on the model class Download Brochure All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Technical Specifications Available Options System Reverse Cycle Capacities Indoor Type Heat Reclaim Ventilator Power Supply Refrigerant VAM-HVE Flyer Our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range. Furthermore, improved external static pressures offer greater design flexibility to support variety of duct layouts. Send the brochure to me. Enter your email below to receive the brochure link in your inbox